제품코드 | G051119 | |
---|---|---|
판매 회사명 | 제이앤디전자 | |
연락처 | 031-577-2280 | |
홈페이지 | - | |
제품홍보관 | - |
iSAST OPEN CT1) Low VA CT (JC / JS / JSC) on primary current digital power
Low VA Split core Current transformer for primary current (1A / 5A output), JSC / JS / JC series applied with precise core split cutting technology. It is designed for strong durability and improves both existed error in low current and error occurred by ‘external vibration and shock’ to minimize tolerance on cutting cross section of core. Rated current is 60A-2400A, it satisfies with IEC60044-1 0.5 / 1.0 / 3.0 grade and ANSI 57.13 0.6 / 1.2 grade. It certifies with security accreditation IEC61010-1, UL61010-1 and EN61010-1 as official document.
2) mA CT
A mA output Split core Current transformer for precise power and energy measuring, JSC / JS / JC series are applied with precise core split cutting technology. It is designed for strong durability and improves both existed error in low current and error occurred by ‘external vibration and shock’ to minimize tolerance on cutting cross section of core. As compact one-touch split structure and built in over-voltage-protection-circuit, it offers best solution to connect on primary current directly for security and fast installation on digital power meter instead of cutting power line. Rated current is 5A-2400A, it satisfies with IEC60044-1 0.5 / 1.0 / 3.0 grade and ANSI 57.13 0.6 / 1.2 grade. It certifies with security accreditation IEC61010-1, UL61010-1 and EN61010-1 as official document.
3) Transducer
Split core Current transducer, RMS/V/VH Series, is designed for energy management, with a convenient connection to electronic submeter. It may also be applied for current measurement in a system of distributed power line carriers (PLCs) or remote controls such as SCADA software for automation and supervision. Other applications include security and condition monitoring, load monitoring, in protection systems, and for predictive maintenance of conveyers, pumps or HVAC motors.
Low VA Split core Current transformer for primary current (1A / 5A output), JSC / JS / JC series applied with precise core split cutting technology. It is designed for strong durability and improves both existed error in low current and error occurred by ‘external vibration and shock’ to minimize tolerance on cutting cross section of core. Rated current is 60A-2400A, it satisfies with IEC60044-1 0.5 / 1.0 / 3.0 grade and ANSI 57.13 0.6 / 1.2 grade. It certifies with security accreditation IEC61010-1, UL61010-1 and EN61010-1 as official document.
2) mA CT
A mA output Split core Current transformer for precise power and energy measuring, JSC / JS / JC series are applied with precise core split cutting technology. It is designed for strong durability and improves both existed error in low current and error occurred by ‘external vibration and shock’ to minimize tolerance on cutting cross section of core. As compact one-touch split structure and built in over-voltage-protection-circuit, it offers best solution to connect on primary current directly for security and fast installation on digital power meter instead of cutting power line. Rated current is 5A-2400A, it satisfies with IEC60044-1 0.5 / 1.0 / 3.0 grade and ANSI 57.13 0.6 / 1.2 grade. It certifies with security accreditation IEC61010-1, UL61010-1 and EN61010-1 as official document.
3) Transducer
Split core Current transducer, RMS/V/VH Series, is designed for energy management, with a convenient connection to electronic submeter. It may also be applied for current measurement in a system of distributed power line carriers (PLCs) or remote controls such as SCADA software for automation and supervision. Other applications include security and condition monitoring, load monitoring, in protection systems, and for predictive maintenance of conveyers, pumps or HVAC motors.